Loading
Search Suggestions: Find Inspiration
Loading
/

Vertical Chillers and Freezers - Cabinet Stability During Earthquakes

Product Group: Upright Chillers and Freezers
Content: Vertical Chillers and Freezers - Cabinet Stability During Earthquakes
Issue Date: 30/0/2016
Customer: General
Bulletin No: SBG0091
Revision: 1.0 (Current version of this bulletin)

Overview

Reduce the chance of injury and damage during an earthquake by ensuring vertical chillers and freezers are positioned securely in place.

Lockable Castors and Stabiliser Feet

Most SKOPE vertical chillers and freezers are fitted with lockable front castors, and some are also fitted with front stabiliser feet. When the cabinet is in position, the front castors should always be locked. To lock the castors, press the pedal on the side of each castor down until the wheel locks in place. Note: Rear castors are not usually fitted with locks. If present, stabiliser feet should be fitted to the mounting screws underneath the front of the cabinet and wound down to make firm contact with the floor.

Restraints

Seismic restraints can also be fitted to the cabinet and an adjacent supporting structure to help support the cabinet during earthquakes. While many systems are available, the staple and chain example below is simple and cost effective.

to fit feert